MITSUBISHI
Home >> Products >> MITSUBISHI >> L series PLC >> Counter module >> LD62D-CM High speed counter module

LD62D-CM High speed counter module

MITSUBISHI LD62D-CM Manual And Instructions
LD62D-CM datasheetPDF datasheet

MITSUBISHI LD62D-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: High speed counter module
Model: LD62D-CM
Number of input channels: 2Ch.
Differential drive input.
Maximum count rate: pulse/s 500K.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized.

"Universal output function: leakage type.
Program capacity: 60K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
CPU built-in functions can be easily set through programming tools LD62D-CM.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool LD62D-CM
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated " LD62D-CM.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators LD62D-CM. "Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Open collector output.
Axis of control: 2.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom LD62D-CM.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same timee LD62D-CM.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format.