LJ71GF11-T2-CM IE CC-Link live network master / local station module

MITSUBISHI LJ71GF11-T2-CM Manual And Instructions
LJ71GF11-T2-CM datasheetPDF datasheet

MITSUBISHI LJ71GF11-T2-CM Product information and technical parameters:
Brand: MITSUBISHI
Name: IE CC-Link live network master / local station module
Model: LJ71GF11-T2-CM
"IE Field CC-Link master / local station
Transmission speed: 1Gbps.
Remote input / output: 16384 points.
Remote register: 8192 words.
Can be applied to the serial number of the top 5 for the "13012" and after the CPU module.
Simply set the parameters, you can easily start the network.
Simply use the Works2 GX, set the network parameters in the 1 master station, you can easily connect all the slave stations.
Also, when you need to change the system, you only need to change the parameters.
High degree of freedom network
Build star, linear, star and linear mixed model, and ring network,
Therefore, can freely set the scene equipment.
When you use HUB, you just need to connect the cable to the free port to build the network easily,
Additional equipment and re layout of the corresponding is also more simple. "

"Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 40ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
CPU built-in functions can be easily set through programming tools LJ71GF11-T2-CM.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool LJ71GF11-T2-CM
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated " LJ71GF11-T2-CM.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators LJ71GF11-T2-CM. "Can be used as a screw relay terminal.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be used as a screw relay terminal.Can be used to locate the wiring between drives.
Trunk terminal available for external input signal. Output points: 16 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called LJ71GF11-T2-CM.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch LJ71GF11-T2-CM.
Communication protocol is a standard Modbus protocol or custom protocol.