MITSUBISHI
Home >> Products >> MITSUBISHI >> CC-LINK IE network >> NZ2GF-CCB Bridge module

NZ2GF-CCB Bridge module

MITSUBISHI NZ2GF-CCB Manual And Instructions
NZ2GF-CCB datasheetPDF datasheet

MITSUBISHI NZ2GF-CCB Product information and technical parameters:
Brand: MITSUBISHI
Name: Bridge module
Model: NZ2GF-CCB
CC-Link IE field network CC-Link bridge module.
Can support Ver.1 CC-Link remote I/O station and remote device station connected to the IE CC-Link field network.
CC-Link parameters can be set by a simple switch operation.
According to the original station number order, will be allocated to the bridge module of link equipment as CC-Link remote station equipment distribution link.
The IE CC-Link field network and the CC-Link loop transmission are independent of each other.
The function module of MELSOFT Library (FB), the cache access bridge module,
To confirm and diagnose the running state of CC-Link.

Type: 18 point terminal.
Input / output mode: Thermocouple Input, transistor output, channel insulation.
Number of stations: 1 stops.
Number of channels: 4 channels.
Sampling period is 250ms/4 channel. Use 1 sets of temperature control module,
Can achieve standard control (heating, cooling) and heating cooling control NZ2GF-CCB.
This module has the functions of heating up, maximum current suppression, self diagnosis and so on NZ2GF-CCB
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module) NZ2GF-CCB.
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Type: sensor connector (e-CON).
Input form: DC input, positive pole common end.
Input points: 16 points.
Rated input voltage / current: DC24V (4mA).
External connection: 3 wire NZ2GF-CCB.
IE CC-Link field network module type remote unit.
Select input response time from 0ms/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms.
High speed input and output control of single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Type: 18 point terminal.
Input type: DC input, the common cathode / negative public end sharing.
Input points: 16 points.
Rated input voltage / current: DC24V (4mA).
External connection: 1 wire.
IE CC-Link field network module type remote unit.
Select input response time from 0ms/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms.
High speed input and output control of single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Caan be connected to the expansion module, more convenient to expand the input and output points NZ2GF-CCB.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Mastter) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station NZ2GF-CCB.