Master / local station sharing.
Corresponding Ver2 CC-Link.
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
The QJ61BT11N module supports CC-Link version 1 and version 2, which can be used as a local station or master station module.
I/O control in the first class of open field network module.
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
4 axis, differential drive output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 4Mpps.
40 pin connector.
Differential output.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing QJ61BT11.
Positioning module.
Open collector output
QJ61BT11
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control QJ61BT11.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance QJ61BT11.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. "10BASE-T/100BASE-TX.
Web servo module for RS-232.
Web server module capable of using Internet / Intranet for remote monitoring and operation of programmable controller.
Use the Internet connected to the PC, just through a simple setup,
Remote monitoring / operation of MELSEC from any location.
Data recording funnction can be used to display and collect data QJ61BT11.
Data can be recorded at the shortest distance of 100ms.
Also has the following functions.
Using email to send data / alarm notification.
Using FTP to transfer / access data files.
The display function of event monitor / history record QJ61BT11.
User authentication /IP filter and other security features.
User can customize the creation of Web pages. "