MITSUBISHI
Home >> Products >> MITSUBISHI >> Q series PLC >> Control network module >> QJ72LP25GE Optical fiber loop (GI) module

QJ72LP25GE Optical fiber loop (GI) module

MITSUBISHI QJ72LP25GE Manual And Instructions
QJ72LP25GE Remote I/O networkReference Manual

MITSUBISHI QJ72LP25GE Product information and technical parameters:
Brand: MITSUBISHI
Name: Optical fiber loop (GI) module
Model: QJ72LP25GE
GI-62.5/125 optical cable.
Double ring.
Remote I/O net (remote I/O station).

Common cathode input module (standard type).SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Controller network (control station / common station) / remote I/O network (remote master station).
With external power supply function.
MELSECNET/H network module capable of composing large scale flexible network system QJ72LP25GE.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station QJ72LP25GE
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference QJ72LP25GE.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.32 point connector for welding (40 pin connector).Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,) QJ72LP25GE.
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function att the same time QJ72LP25GE.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process QJ72LP25GE.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.


...More relevant models >>>>