MITSUBISHI
Home >> Products >> MITSUBISHI >> QS safety series >> QS90SR2SP-Q Safety relay module

QS90SR2SP-Q Safety relay module

MITSUBISHI QS90SR2SP-Q Manual And Instructions
QS90SR2SP-Q datasheetPDF datasheet
QS90SR2SP-Q User's Manual
QS90SR2SP-Q Safety Application Guide
QS90SR2SP-Q Safety Guideline
QS90SR2SP-Q Safety Guideline

MITSUBISHI QS90SR2SP-Q Product information and technical parameters:
Brand: MITSUBISHI
Name: Safety relay module
Model: QS90SR2SP-Q
Application: Q series.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Add up to 3 additional units: safety relay module.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file.

Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL, CL3 SIL3.
Performance level: PLe.
EFI connecting port number: 2.
EFI connection method: spring clip terminal table connection.
Setting interface: RS-232.
Use special setting monitoring tools to configure the configuration directly QS90SR2SP-Q.
Constitute a rich set of components can be easily and quickly set the hardware structure QS90SR2SP-Q
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file QS90SR2SP-Q. Safety installation number on the controller: up to 2 units (total WSO-GETH00200 and WSO-GCC100202)
Network type: Ethernet (TCP/IP).
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic QS90SR2SP-Q.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL3.
Performance level: PLe.
PFHd:0.4E-091/h.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Speed of delivery: optional 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps.
Connect up to 64 sets of units.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures QS90SR2SP-Q.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down QS90SR2SP-Q.