MITSUBISHI
Home >> Products >> MITSUBISHI >> R series PLC >> Input / output module >> RY40PT5P output module

RY40PT5P output module

MITSUBISHI RY40PT5P Manual And Instructions
RY40PT5P datasheetPDF datasheet

MITSUBISHI RY40PT5P Product information and technical parameters:
Brand: MITSUBISHI
Name: output module
Model: RY40PT5P
Output points: 16 points.
Output form: Transistor (source) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.5A/ point.
Response time: 1ms.
Common way: 16 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 18 point screw terminal.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance.

The input power supply voltage: AC100 ~ 240V.
Input frequency: 50/60Hz plus or minus 5%.
Input maximum apparent power: 120VA.
Maximum input power: -.
Rated output current (DC5V): 3.5A.
Rated output current (DC24V): 0.6.
IQ-R MELSEC series consists of CPU module, power module, substrate module, input and output module, intelligent function module and so on RY40PT5P.
For the entire system, the substrate module can be expanded to 7 levels, up to 64 modules can be installed,
Therefore, large scale system can be constructed RY40PT5P In addition, by using the RQ extended substrate module,
The sea can also effectively use the MELSEC-Q series of modules of the asset. "Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0 RY40PT5P. 1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: plus or minus 15V.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000 RY40PT5P.
Current input
Analog input current: -.
Digital output value: -.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Reduce downtime and reduce maintenance costs through anomaly detection
Works3 GX can be useed to easily set the critical value of the input and output signals RY40PT5P.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs.
Channel insulation can ensure the accurate signal transceiver.
Model withh " -G " module in the channel between the insulation,
Isolation amplifiers are not required to prevent inter channel current and interference current RY40PT5P.


...More relevant models >>>>