MITSUBISHI
Home >> Products >> MITSUBISHI >> R series PLC >> Input / output module >> RY41PT1P output module

RY41PT1P output module

MITSUBISHI RY41PT1P Manual And Instructions
RY41PT1P datasheetPDF datasheet

MITSUBISHI RY41PT1P Product information and technical parameters:
Brand: MITSUBISHI
Name: output module
Model: RY41PT1P
Output points: 32 points.
Output form: Transistor (source) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.1A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 40 pin connector.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance.

Differential input, transistor (drain type) output.
Channel number: 2CH.
External wiring connection mode: 40 pin connector
Count input signal: there
Single phase input (single frequency / double frequency)
Dual phase input (single frequency and double frequency /4)
CW/CCW input: there
The signal level (phi A, Phi B): EIA standard RS-422-A differential line driver level RY41PT1P.
PWM output function can be output through the highest frequency of 200kHz, minimum ON 100ns width of the PWM waveform of any duty cycle RY41PT1P
In addition, the output cycle and duty cycle can be changed when the output PWM,
The use of the most suitable for the use of continuous PWM signal flow control. Analog input channel number: 8CH RY41PT1P.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Common
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: plus or minus 15V.
External wiring connection mode: 18 point screw terminal.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000 RY41PT1P.
Current input
Analog input current: -.
Digital output value: -.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Reduce downtime and reduce maintenance costs through anomaly detection
Works3 GX can be useed to easily set the critical value of the input and output signals RY41PT1P.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs.
Channel insulation can ensure the accurate signal transceiver.
Model withh " -G " module in the channel between the insulation,
Isolation amplifiers are not required to prevent inter channel current and interference current RY41PT1P.


...More relevant models >>>>