Protective film for 10.4 inch screen.
Transparent, 5.
Applicable model: GT12. Number of input channels: 8ch.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup
HC-SF201B
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected. Power: 7.5kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. Output points: 8 points.
Output voltage and current: AC100 ~ 240V, 0.6A/1 point, 4A/1 public end.
Response time: 0.5Hz+1ms.
Output form: bidirectional thyristor output.
8 point /1 a public side.
26 point terminal station.
Number of stations: 1 stops.
Type remote I/O units outside of the panel (optical data connection).
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system.
At the same time, the use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information.
HC-SF201B Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HC-SF201B&select=5