Uses: for external BCD or binary digital signal to do the frequency of a given.
Applicable frequency converter: FR-A700, FR-F700, FR-E700"MITSUBISHI general purpose AC servo amplifier MR-J2 series.
Rated output: 3.5kw.
Interface: SSCNET type.
Voltage: three phase AC200V.
MR-J2 series server system has the ability to carry out a higher precision control,
Using high performance CPU, greatly improve the responsiveness of the product,
Speed loop frequency response increased to 550HZ
HC-SF301B
Various series of servo motors are suitable for different control requirements,
The encoder on the servo motor supports ABS mode,
As long as the servo amplifier on the other plus batteries,
Can form an absolute position system. Motor series: low inertia, medium power.
Rated output power: 22.0kw.
Rated speed: 2000r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Voltage: 400V type.
Protection level: IP65 (IP67).
Features: low inertia from low speed to high speed, three modes can be selected, suitable for different application range. As a standard port, 30KW or greater power is suitable for flange (type) installation and support foot mounting.
Application example: injection molding machine, semiconductor manufacturing equipment, large conveyor machinery.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring. Input and output points: 480 points.
Input / output data points: 480 points.
Program capacity: 8k.
Basic command processing speed (LD command) s:1.25.
RAM memory capacity: 32K, power supply (DC24V).
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
HC-SF301B Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HC-SF301B&select=5