Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. 1 axis servo amplifier.
MITSUBISHI general AC servo amplifier MELSERVO-J4 series.
Rated output: 7.0kw.
Interface: SSCNET III /H.
Power supply: three phase AC200V.
Special specification: full closed loop control 4 wire / device end encoder ABZ phase input corresponding support function security unit, support positioning mode
QD75D4N
Servo amplifier supporting SSCNET III /H.
Complete synchronization system capable of using high speed serial optical communication.
Can be combined with the servo system controller to maximize the performance of the servo system.
Improve mechanical properties by high performance motor.
By improving the resolution and processing speed of the encoder,
The rotating servo motor has higher precision and better performance of rotation.
Only open a key type of adjustment function, can be carried out including mechanical resonance filter, high end seismic control II, low pass filter servo gain adjustment.
Easily start advanced seismic function, it can maximize the mechanical properties.
It can automatically adjust the required response settings automatically. Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to the field components that require only ON/OFF control,
Such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data.
Remote components: the field components that require processing of register data,
For example analog I/O and counter, etc..
In this type of component, in addition to the bit data can be carried out in the register data communication.
Intelligent remote: this type of element refers to the actions that allow the master station or other station to access,
To collect data and control the local PLC station,
GOTS and programmer interface unit are of this type.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work.
QD75D4N Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=QD75D4N&select=5