MITSUBISHI
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> MELSECNET/MINI-S3 master module >> A1SJ71PT32-S3 Master control module

A1SJ71PT32-S3 Master control module

MITSUBISHI A1SJ71PT32-S3 Manual And Instructions
A1SJ71PT32-S3 datasheetPDF datasheet
A1SJ71PT32-S3 User's Manual
A1SJ71PT32-S3 HardwareUser's Manual

MITSUBISHI A1SJ71PT32-S3 Product information and technical parameters:
Brand: MITSUBISHI
Name: Master control module
Model: A1SJ71PT32-S3
Cable type: cable or twisted pair.
A1SJ71PT32-S3 and A1SJ71PT32-S3 are the main control module of MELSECNET/MINI-S3,
The main PLC in the network can control 64 remote I/O modules.
The main control module carries on the high speed data communication to the remote module on the connection network.
Each PLCCPU can use a number of main control modules,
But up to no more than the maximum allowed by the main I/O CPU points.
A1SJ71PT32-S3 can be used in the cable system can also be used in twisted pair cable system;
A1SJ71T32-S3 can only be used in twisted pair cable network.
The popularization and application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment.
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram. Its characteristics are basically consistent with the ladder diagram language.

RS-232 1 channel.
RS-422/485 1 channel.
Transmission speed: 2 channels.
At the same time the use of 115.2kbps may.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program A1SJ71PT32-S3.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register A1SJ71PT32-S3
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive A1SJ71PT32-S3.
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
User memory: user program storage area and work data storage area A1SJ71PT32-S3.
Composed of random access memory (RAM). User use.
Power cut off. Commonly used efficient lithium battery as a backup power supply, life is generally 3~5 years. Temperature sensor: PT100, 3 wire system.
The A1S62RD3 and A1S62RD4 temperature sensor input modules allow the platinum resistance temperature sensing element to be directly connected to the PLC,
This component converts a signal from a temperature measuring element to a numeric value that represents a temperature measurement value,
This temperature value can be used for the control process.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PPLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on A1SJ71PT32-S3 A1SJ71PT32-S3.
This phenomenon is called the I/O delay time effect.