FR-D740-2.2K-CHT 3 phase 400V converter

MITSUBISHI FR-D740-2.2K-CHT Manual And Instructions
FR-D740-2.2K-CHT datasheetPDF datasheet
FR-D740-2.2K-CHT BASICInstruction manual

MITSUBISHI FR-D740-2.2K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-D740-2.2K-CHT
MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 2.2KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.

Power: 3.7kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor FR-D740-2.2K-CHT.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table FR-D740-2.2K-CHT
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor FR-D740-2.2K-CHT.
The installation of thermal relay, to avoid overheating and burn the braking resistor. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 45KW.
Frequency converter common frequency of a given way: the operator keyboard is given, the contact signal given, analog signal given, the pulse signal given and communication methods given, etc FR-D740-2.2K-CHT. .
These frequencies have their advantages and disadvantages, and should be selected according to the actual needs.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 3.7kw.
SLD converter rated current: 12.6A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation oof the inverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements FR-D740-2.2K-CHT.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out FR-D740-2.2K-CHT.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "