Control axis: maximum 8 axes.
Teaching running function: there (when using SV13).
To stop the speed control function at the specified location.
Can be set in advance to stop the location.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / deceleration time.
Phase compensation function.
The mixed function of virtual mode and real mode.
Master / local station sharing.
Corresponding Ver2 CC-Link.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of Q172HCPU-T
Q172HCPU-T
Even if the information reaches saturation, it will not affect the link scan time.
The QJ61BT11N module supports CC-Link version 1 and version 2, which can be used as a local station or master station module.Input: 4 channels Q172HCPU-T.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q172HCPU-T.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion moldingg machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q172HCPU-T.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q172HCPU-T.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.