MITSUBISHI
Home >> Products
MITSUBISHI
Programmable logic controller CPU
R16ENCPU


Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Programmable logic controller CPU
R32ENCPU


Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Programmable logic controller CPU
R120ENCPU


Operation control mode: stored procedure repeated operation. Built in IE CC-Link. Input / output poi
MITSUBISHI
Movement CPU
R16MTCPU


"Axis of control: 16. Program language: motion SFC, special instruction. Servo program capacity: 32K
MITSUBISHI
Movement CPU
R32MTCPU


"Axis of control: 32. Program language: motion SFC, special instruction. Servo program capacity: 32K
MITSUBISHI
Safety CPU
R08SFCPU-SET


Safety grade (SIL): SIL 3 (IEC 61508). Performance level (PL): e PL (13849-1 EN/ISO). Operation cont
MITSUBISHI
Safety CPU
R16SFCPU-SET


Safety grade (SIL): SIL 3 (IEC 61508). Performance level (PL): e PL (13849-1 EN/ISO). Operation cont
MITSUBISHI
Safety CPU
R32SFCPU-SET


Safety grade (SIL): SIL 3 (IEC 61508). Performance level (PL): e PL (13849-1 EN/ISO). Operation cont
MITSUBISHI
Safety CPU
R120SFCPU-SET


Safety grade (SIL): SIL 3 (IEC 61508). Performance level (PL): e PL (13849-1 EN/ISO). Operation cont
MITSUBISHI
C language controller module
R12CCPU-V


Memory capacity: 256MB. As one of the specific features of the iQ-R CPU series MELSEC module, the ne
MITSUBISHI
Main base plate
R35B


The input and output module installation number: 5. DIN guide rail mounting adapter type: R6DIN1. Si
MITSUBISHI
Main base plate
R38B


The input and output module installation number: 8. DIN guide rail mounting adapter type: R6DIN1. Si
MITSUBISHI
Main base plate
R312B


The input and output module installation number: 12. DIN guide rail mounting adapter type: R6DIN1. S
MITSUBISHI
Extended substrate
R65B


The input and output module installation number: 5. Can install module: iQ-R MELSEC series module. D
MITSUBISHI
Extended substrate
R68B


The input and output module installation number: 8. Can install module: iQ-R MELSEC series module. D
MITSUBISHI
Extended substrate
R612B


The input and output module installation number: 12. Can install module: iQ-R MELSEC series module.
MITSUBISHI
RQ extended substrate
RQ65B


The input and output module installation number: 5. Can install module: MELSEC-Q series module. DIN
MITSUBISHI
RQ extended substrate
RQ68B


The input and output module installation number: 8. Can install module: MELSEC-Q series module. DIN
MITSUBISHI
RQ extended substrate
RQ612B


The input and output module installation number: 12. Can install module: MELSEC-Q series module. DIN
MITSUBISHI
Extension cable
RC06B


"The length of the cable: 0.6 meters. IQ-R MELSEC series of "inter module synchronization", refers t
MITSUBISHI
Extension cable
RC12B


"The length of the cable: 1.2 meters. IQ-R MELSEC series of "inter module synchronization", refers t
MITSUBISHI
Adapter for DIN rail mounting
R6DIN1


Main base plate, extended substrate mounting.
MITSUBISHI
Blind cover plate
RG60


Blind cover plate for main substrate and extended substrate I/O slot.
MITSUBISHI
Power module
R62P


The input power supply voltage: AC100 ~ 240V. Input frequency: 50/60Hz plus or minus 5%. Input maxim
MITSUBISHI
Power module
R64P


The input power supply voltage: AC100 ~ 240V. Input frequency: 50/60Hz plus or minus 5%. Input maxim
MITSUBISHI
Input module
RX42C4


"Enter points: 64 points. Rated input voltage and frequency: DC24V. Rated input current: TYP 4.0mA.
MITSUBISHI
High speed input module
RX40PC6H


Input points: 16 points. Rated input voltage and frequency: DC24V. Rated input current: 6.0mA. Respo
MITSUBISHI
High speed input module
RX40NC6H


Input points: 16 points. Rated input voltage and frequency: DC24V. Rated input current: 6.0mA. Respo
MITSUBISHI
output module
RY10R2


Output points: 16 points. Output form: relay output. Rated open and close voltage, current: DC24V/2A
MITSUBISHI
output module
RY40NT5P


Output points: 16 points. Output form: Transistor (drain type) output. Rated open and close voltage,
MITSUBISHI
output module
RY41NT2P


Output points: 32 points. Output form: Transistor (drain type) output. Rated open and close voltage,
MITSUBISHI
output module
RY42NT2P


Output points: 64 points. Output form: Transistor (drain type) output. Rated open and close voltage,
MITSUBISHI
output module
RY40PT5P


Output points: 16 points. Output form: Transistor (source) output. Rated open and close voltage, cur
MITSUBISHI
output module
RY41PT1P


Output points: 32 points. Output form: Transistor (source) output. Rated open and close voltage, cur
MITSUBISHI
output module
RY42PT1P


Output points: 64 points. Output form: Transistor (source) output. Rated open and close voltage, cur
MITSUBISHI
Analog input module
R60ADV8


Analog input channel number: 8CH. accuracy Ambient temperature of 25 plus or minus 5 degrees C: plus
MITSUBISHI
Analog input module
R60ADI8


Analog input channel number: 8CH. accuracy Ambient temperature of 25 plus or minus 5 degrees C: plus
MITSUBISHI
Analog input module
R60AD8-G


Analog input channel number: 8CH. accuracy Ambient temperature of 25 plus or minus 5 degrees C: plus
MITSUBISHI
Analog input module
R60AD16-G


Analog input channel number: 16CH. accuracy Ambient temperature of 25 plus or minus 5 degrees C: plu
MITSUBISHI
Temperature input module
R60TD8-G


Analog input channel number: 8CH. Cold end compensation accuracy: plus or minus 1. Available thermoc
MITSUBISHI
Temperature input module
R60RD8-G


Analog input channel number: 8CH. Cold end compensation precision. Available thermocouple: -. Availa
MITSUBISHI
Temperature control module
R60TCTRT2TT2


Analog input channel number: 4CH. Available thermocouple: B, R, S, K, E, J, T, N, U, L, PL II, W5Re/
MITSUBISHI
Input / output mixed module
RH42C4NT2P


Input: DC input. Input points: 32 points. Rated input voltage: DC24V Rated input current: 4 TYP. Response time: 0.1 ~ 70ms. Common way: 32 points, the public side. Interrupt function: have. Output: Transistor (drain type) output. Output points: 32 points Rated load voltage: DC12 ~ 24V. Max load current: 0.2A/ point. Response time: 1ms. Common way: 32 point / public end. Protection function (overload, overheat) Common。
MITSUBISHI
Temperature control module
R60TCTRT2TT2BW


Analog input channel number: 4CH. Available thermocouple: B, R, S, K, E, J, T, N, U, L, PL II, W5Re/
MITSUBISHI
Temperature control module
R60TCRT4BW


Analog input channel number: 4CH. Available thermocouple: -. Available temperature resistance: PT100
MITSUBISHI
Analog output module
R60DA4


Analog output channel number: 4CH. accuracy Ambient temperature of 25 plus or minus 5 degrees C: plu
MITSUBISHI
Analog output module
R60DAV8


Analog output channel number: 8CH. accuracy Ambient temperature of 25 plus or minus 5 degrees C: plu
MITSUBISHI
Analog output module
R60DA8-G


Analog output channel number: 8CH. accuracy Ambient temperature of 25 plus or minus 5 degrees C: plu
MITSUBISHI
Analog output module
R60DA16-G


Analog output channel number: 16CH. accuracy Ambient temperature of 25 plus or minus 5 degrees C: pl
MITSUBISHI
Simple motion module
RD77MS2


Axis of control: 2. Operation cycle: 0.444ms, 0.888ms, 1.777ms, 3.555ms. Control unit: mm, inch, deg
MITSUBISHI
Simple motion module
RD77MS4


Axis of control: 4. Operation cycle: 0.444ms, 0.888ms, 1.777ms, 3.555ms. Control unit: mm, inch, deg
MITSUBISHI
Simple motion module
RD77MS8


Axis of control: 8. Operation cycle: 0.444ms, 0.888ms, 1.777ms, 3.555ms. Control unit: mm, inch, deg
MITSUBISHI
Simple motion module
RD77MS16


Axis of control: 16. Operation cycle: 0.444ms, 0.888ms, 1.777ms, 3.555ms. Control unit: mm, inch, de
MITSUBISHI
Positioning module
RD75P2


"Transistor output. Axis of control: 2. Control unit: mm, inch, degree, pulse. Location data: 600 da
MITSUBISHI
Positioning module
RD75P4


"Transistor output. Axis of control: 4. Control unit: mm, inch, degree, pulse. Location data: 600 da
MITSUBISHI
Positioning module
RD75D2


"Differential driver output. Axis of control: 2. Control unit: mm, inch, degree, pulse. Location dat
MITSUBISHI
Positioning module
RD75D4


"Differential driver output. Axis of control: 4. Control unit: mm, inch, degree, pulse. Location dat
MITSUBISHI
High speed counter module
RD62P2


DC input, transistor (drain type) output. Channel number: 2CH. External wiring connection mode: 40 p
MITSUBISHI
Serial communication module
RJ71C24


230.4kbps RS-232, Max. 1 channel, RS-422/485 1 channel. When using the serial communication module,
MITSUBISHI
Serial communication module
RJ71C24-R2


230.4kbps Max., RS-232 2 channel. When using the serial communication module, it is only necessary t
MITSUBISHI
Serial communication module
RJ71C24-R4


230.4kbps Max., RS-422/485 2 channel. When using the serial communication module, it is only necessa
MITSUBISHI
MES interface module
RD81MES96


"Database sharing. FA integration solution "e-F@ctory" to achieve development, production, and maint
MITSUBISHI
Secure CPU module
QS001CPU


Control mode: loop program execution. Input / output control mode: refresh mode. Programming languag
MITSUBISHI
Safety power module
QS061P-A2


Board module installation location: QS series power module mounting slot. Suitable substrate module:
MITSUBISHI
Safety bottom plate module
QS034B


The input and output module installation number: 4. Could extend the connection: not to extend the c
MITSUBISHI
IE CC-Link live network master module and local module (with security features)
QS0J71GF11-T2


"The most common station 11 units connected network: 121. The 11 largest network connection units se
MITSUBISHI
Safety CC-Link system master module
QS0J61BT12


Speed of delivery: optional 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps. Connect up to 64 sets of units. Se
MITSUBISHI
Safety CC-Link system remote I/O module
QS0J65BTB2-12DT


Input points: 8 points (dual input), 16 points (single input). Isolation mode: photoelectric couplin
MITSUBISHI
Safety CC-Link system remote I/O module
QS0J65BTS2-8D


Input points: 8 points (dual input), 16 points (single input). Isolation mode: photoelectric couplin
MITSUBISHI
Safety CC-Link system remote I/O module
QS0J65BTS2-4T


Output points: 4 points (select the source type + drain type), 2 points (select the source type + so
MITSUBISHI
Secure I/O module
WS0-XTIO


Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1). Security level: SIL3. Performance level: PL
MITSUBISHI
cpu module
WS0-CPU1


Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1). Security level: SIL, CL3 SIL3. Performance
MITSUBISHI
Ethernet interface module
WS0-GETH00200


Safety installation number on the controller: up to 2 units (total WSO-GETH00200 and WSO-GCC100202)
MITSUBISHI
CC-Link interface module
WS0-GCC100202


Transmission speed: 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps (automatic tracking). Station No.: 1~64 sta
MITSUBISHI
Safety relay output module
WS0-4RO


Functional security based on EN954: category 4. Functional security based on SIL3: IEC61508. Use spe
MITSUBISHI
Safety relay module
QS90SR2SP-Q


Application: Q series. Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1. Security inpu
MITSUBISHI
Safety relay module
QS90SR2SN-Q


Application: Q series. Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1. Security inpu
MITSUBISHI
Safety relay module
QS90SR2SP-CC


Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO. Safe input points: 1 points (2 input). Sta